Impact Factor: 1.2

Article

Images in cardiology

REC Interv Cardiol. 2024;6:253-255

Anterior AMI with an unusual angiographic image

IAM anterior con imagen angiográfica inusual

Angie Tatiana Ariza-Mosquera,a,b, Manuel López Pérez,a Fernando Sabatel-Pérez,a Teresa Gil Jiménez,a Gerardo Moreno Terribas,a,c and Juan Caballero-Borregoa,c

aDepartamento de Cardiología, Hospital Universitario Clínico San Cecilio, Granada, Spain

bFundación para la Investigación Biosanitaria en Andalucía Oriental (FIBAO), Granada, Spain

cInstituto de Investigación Biosanitaria de Granada (Ibs Granada), Granada, Spain

A 53-year-old male smoker with hypertension and a family history of dyslipidemia and early ischemic heart disease in family members was diagnosed with anterior ST-segment elevation acute coronary syndrome (STEACS) in 2017. He was treated with a 4 mm × 18 mm everolimus-eluting stent implanted in the proximal left anterior descending coronary artery and 2 overlapping distal stents. The procedure was uneventful, and the remaining arteries showed ectasia with diffuse atheromatous disease. An echocardiogram revealed the presence of mild left ventricular systolic dysfunction. The patient was readmitted after experiencing a new anterior STEACS due to very late thrombosis of the previous stent in the proximal left anterior descending coronary artery, where an external calcified image was found around the stent (figure 1A,B: arrows). The study was completed with optical coherence tomography (figure 2A,B), which revealed the presence of abundant thrombotic content, and stent malapposition, without visualization of the surrounding arterial wall, indicating a large thrombosed and calcified aneurysm. Thrombus aspiration and a drug-coated balloon were used, along with glycoprotein IIb-IIIa inhibitors, resulting in final TIMI grade 3 flow. Computed tomography (figure 3: arrows) performed during admission confirmed the presence of a 24 mm coronary aneurysm with a thrombosed sac. The patient progressed favorably and was discharged from the hospital.


Figure 1.



Figure 2.



Figure 3.


Coronary aneurysms are a rare finding whose incidence ranges from 0.1% to 4.9%. The etiology can be atherosclerotic, congenital, or inflammatory. In our case, atherosclerotic etiology was suspected. However, it could have been intensified by an everolimus-related toxic effect due to hypersensitivity following stenting. This effect is less likely since it was not found in other treated segments, and ectasia was present in the remaining arteries (figure 1C-D; videos 1-2 of the supplementary data). Treatment consisted of indefinite dual antiplatelet therapy after confirming the absence of lack of endothelialization across the aneurysm neck.

FUNDING

None declared.

ETHICAL CONSIDERATIONS

The patient’s prior written informed consent was obtained, and possible sex and gender variables were taken into account following SAGER guidelines.

STATEMENT ON THE USE OF ARTIFICIAL INTELLIGENCE

No artificial intelligence tools were used in the preparation of this manuscript.

AUTHORS’ CONTRIBUTIONS

All authors contributed to the drafting of the article. A.T. Ariza-Mosquera, and F. Sabatel-Pérez wrote the text. F. Sabatel-Pérez, M. López-Pérez, and T. Gil-Jiménez were involved in the review and supervision process. G. Moreno Terribas and J. Caballero-Borrego critically revised the manuscript.

CONFLICTS OF INTEREST

None declared.

SUPPLEMENTARY DATA



Vídeo 1. González Lizarbe S. DOI: 10.24875/RECICE.M23000368



Vídeo 2. González Lizarbe S. DOI: 10.24875/RECICE.M23000368

* Corresponding author.

E-mail address: angietatiana9304@gmail.com (A.T. Ariza-Mosquera).

  @AngieTa01008768

Original articles

Recic Uk 23 096 F2

Review Articles


Original articles

Recic Uk 23 110 F1
Recic Uk 23 132 F2

Editorials

Recic Uk 23 117 F2

Debate

“Orbiting” around the management of stable angina

Recic 24 016 F1
Recic 24 010 F1